e5c40bbb8c Add MHI aircon manual control (Phase 2, Modbus only)
Manual on/off/mode/setpoint/fan control for MHI indoor units via the
already-verified Intesis Modbus TCP gateway, deliberately NOT wired into
the NewBook-driven scheduler yet — that stays deferred. Modbus doesn't
depend on the MQTT broker (separate infra, still unbuilt), so this can be
deployed and tested standalone.

- mhi_gateways table (connection config: host/port/slave id/address base)
  + zone_devices columns for MHI devices (gateway id, unit index, IU hint,
  and the per-device register map staged from a MAPS import — ground
  truth, never re-derived from room/IU at runtime)
- drivers/mhi-modbus.js: discover/getStatus/setTarget over modbus-serial,
  same interface as trv.js/homeassistant.js; per-gateway request queue
  since Modbus TCP requires serialised requests; falls back to the
  profile's stride formula (with a loud warning) only if a unit has never
  been through an import
- routes/mhi-gateways.js: gateway CRUD, live test-connection, xlsx import
  (stages the parsed result for review — never auto-creates devices),
  per-unit 'assign to zone' as the explicit commit step
- routes/override.js: GET .../mhi-status, POST .../mhi-control (control cap)
- frontend: GatewaysPanel (add gateway, test connection, import + preview,
  assign units) and MhiControlPanel (on/off, mode, setpoint, fan) wired
  into Devices.tsx / ZoneDetailModal.tsx

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>